And here's the bug, caught red handed.

We start with the MDIO transceiver being busy with a read of address 0x00. The read data register is still 0x7949, the previous value, because the read is still in progress.

At T=7862 the MCU begins a 4-word burst read of REG_DP_MDIO (0x004c). This is a 32-bit little endian register with the read value in the low 16 bits, a bunch of write-only configuration, and a busy flag in the MSB.

By T=7887 when we read SPI address 0x004f (where the busy flag is) the read has just finished.

So the MCU thinks it's successfully read the whole register.

The fix is pretty simple: latch the busy flag when address 0x4c is read (the entire 32-bit register has to be read in one go, byte access is not supported). The MCU will then read {busy, 0x7949} just like it did on the previous poll, then read the correct value on the subsequent polling cycle.